Parameter
Possible values
Default
Description
Skew
Smoothing time
0 ... 10 s
0.00
Smoothing time for smoothing of the skew
measured value
Skew2
Offset
-180° ... +180°
0.00
Calibration value for the Skew2 measured
value
Skew2
Smoothing time
0 ... 10 s
0.00
Smoothing time for smoothing of the Skew2
measured value
Distance
Smoothing time
0 ... 10 s
0.00
Smoothing time for the distance measured
value
Limit
Parameter
Possible values
Default
Description
Reflector distance
Min.
10 ... 100 000 mm
100 mm
The reflector distance must be at least as high
as the set value. Otherwise the reflector dis‐
tance will be set to this value.
Reflector distance
Max.
10 ... 100 000 mm
64 000 mm
The reflector distance must not be higher
than the set value. Otherwise it will be set to
this value.
Note
Limit
These two parameters are used as an additional plausibility check. They can prevent a pattern
which is similar to a reflector but which is situated outside the possible distance range from
being incorrectly detected as a reflector.
If the set maximum or minimum limit is violated, a corresponding status bit is set (see tables in
the chapter Principle of data exchange for PROFINET IO (Page 121)).
Parameterization
8.2 Application
SIMOCRANE CenSOR
Operating Instructions, 07/2021
85
Summary of Contents for 6GA7202-2AA10-1BF1
Page 2: ......
Page 8: ...Table of contents SIMOCRANE CenSOR 6 Operating Instructions 07 2021 ...
Page 10: ...Introduction SIMOCRANE CenSOR 8 Operating Instructions 07 2021 ...
Page 62: ...Commissioning 7 3 Setting up the camera SIMOCRANE CenSOR 60 Operating Instructions 07 2021 ...
Page 158: ...Appendix A 3 Standards and certifications SIMOCRANE CenSOR 156 Operating Instructions 07 2021 ...
Page 168: ...Index SIMOCRANE CenSOR 166 Operating Instructions 07 2021 ...