Note
Standard product
The standard product is supplied with a 35 mm lens.
8.4.2.3
Diagnostics & monitoring
In this area, you determine the information to be stored for diagnostic purposes.
Logging
In this group, you specify the images to be stored in the camera and the form in which they will
be stored. This includes:
• Saving the images in the camera
• Saving the diagnostics events in the camera
Note
Back up diagnostic data
Back up your diagnostic data before you change the camera to setup mode.
If you have set the buffer type "Ring" for logging pictures, pictures acquired in setup mode can
overwrite pictures you have already recorded.
Table 8-28
Logging
Parameter
Possible values
Default
Description
Image
Buffer type
• Ring
• Stack
Ring
Type of buffer:
• Ring
When the buffer contains 50 entries, entries 1, 2, ...
are overwritten.
• Stack
When the buffer contains 50 entries, no further
entries are made.
Parameterization
8.4 Settings
SIMOCRANE CenSOR
100
Operating Instructions, 07/2021
Summary of Contents for 6GA7202-2AA10-1BF1