Controller Area Network
LH75400/01/10/11 (Preliminary) User’s Guide
22-20
6/17/03
22.3.2.10 Error Warning Limit Register
ELWR is the Error Warning Limit Register. The ELWR Register defines the number of
errors after which an Error Warning Interrupt is generated, if enabled. The EWLR Register
can only be written to in Reset Mode. In Operating Mode, it is Read Only.
Changes made during Reset Mode take effect when the CAN Controller returns to
Operating Mode. The default value of this register after System Reset is 0110000 (i.e., 96).
Table 22-23. EWLR Register
BIT
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
FIELD
///
RESET
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
RW
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
BIT
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
FIELD
///
EWL.7
EWL.6
EWL.5
EWL.4
EWL.3
EWL.2
EWL.1
EWL.0
RESET
0
0
0
0
0
0
0
0
0
1
1
0
0
0
0
0
RW
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
ADDR
0xFF 0x34
Table 22-24. EWLR Register Definitions
BIT
NAME
DESCRIPTION
31:8
///
Reserved
Writing to these bits has no effect. Reading returns 0.
7:0
EWL.7 - EWL.0
Errors Before Interrupt
Specifies the number of errors after which an
error-warning interrupt should be generated.