Real-Time Clock
LH75400/01/10/11 (Preliminary) User’s Guide
17-8
6/17/03
17.3.2.6 Read/Write Load Register 0
LR0 is the Lower 16-bit Read/Write Load Register. Writes to this register load the least-
significant 16 bits of an Intermediate Register. The intermediate Register is not loaded into
the free-running counter until the rising edge of a 1 Hz clock follows a write operation to
LR1. Read operations return the last value written.
NOTE: The reset value of this register’s bits is indeterminate.
Table 18. LR0 Register
BIT
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
FIELD
///
RESET
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
RW
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
BIT
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
FIELD
RTCLR0
RESET
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
ADDR
0xFF 0x14
Table 19. LR0 Register Definitions
BIT
NAME
FUNCTION
31:16
///
Reserved
15:0
RTCLR0 RTC Load Register 0
Specifies the lower 16-bit Counter Load Register.