60
MOVIDRIVE
®
MD_60A Operating Instructions
Complete parameter list
3__
MOTOR PARAMETERS
30_
Limits 1
31_ Limits 2
300/ Start/stop speed 1
0 – 60 – 150 rpm
310 Start/stop speed 2
0 – 60 – 150 rpm
301/ Minimum speed 1
0 – 60 – 5500 rpm
311 Minimum speed 2
0 – 60 – 5500 rpm
302/ Maximum speed 1
0 – 1500 – 5500 rpm
312 Maximum speed 2
0 – 1500 – 5500 rpm
303/ Current limit 1
0 – 150%I
N
313 Current limit 2
0 – 150%I
N
304
Torque limit
0 – 150 %
32_
Motor compensat. 1 (asynchr.)
33_ Motor compensat. 2 (asynchr.)
320/
Automatic adjustment
1
ON / OFF
330
Automatic adjustment
2
ON / OFF
321
Boost 1
0 – 100 %
331 Boost 2
0 – 100 %
322
IxR compensation 1
0 – 100 %
332 IxR compensation 2
0 – 100 %
323
Premagnetizing time 1 0 – 0.1 – 2 s
333 Premagnetizing time 2 0 – 0.1 – 2 s
324
Slip compensation 1
0 – 500 rpm
334 Slip compensation 2
0 – 500 rpm
34_
Motor protection
340
Motor protection 1
ON / OFF
342 Motor protection 2
ON / OFF
341
Cooling type 1
FAN COOLED / forced-
cooling
343 Cooling type 2
FAN-COOLED / forced-
cooling
35_
Motor sense of rotation
350
Change direction
of rotation 1
ON / OFF
351
Change direction
of rotation 2
ON / OFF
360
Startup
YES / NO
Only available in DBG11A, not in MOVITOOLS/SHELL!
4__
REFERENCE SIGNALS
40_
Speed reference signal
400
Speed reference value 0 – 1500 – 5000 rpm
401
Hysteresis
0 – 100 – 500 rpm
402
Delay time
0 – 1 – 9 s
403
Signal = "1" if:
n < n
ref
/ n > n
ref
41_
Speed window signal
410
Window center
0 – 1500 – 5000 rpm
411
Range width
0 – 5000 rpm
412
Delay time
0 – 1 – 9 s
413
Signal = "1" if:
INSIDE / OUTSIDE
42_
Speed setp./act. val. comp.
420
Hysteresis
1 – 100 – 300 rpm
421
Delay time
0 – 1 – 9 s
422
Signal = "1" if:
n <> n
setpt
/ n = n
setpt
43_
Current reference signal
430
Current reference
value
0 – 100 – 150 % I
N
431
Hysteresis
0 – 5 – 30 % I
N
432
Delay time
0 – 1 – 9 s
433
Signal = "1" if:
I<I
ref
/ I>I
ref
44_
Imax signal
440
Hysteresis
0 – 5 – 50 % I
N
441
Delay time
0 – 1 – 9 s
442
Signal = "1" if:
I = I
max
/ I < I
max
Par.
Name
Setting range
Factory setting
After
startup
Par.
Name
Setting range
Factory setting
After
startup
Variable par.
Parameter set 1
Parameter set 2
0
0
I
Summary of Contents for MOVIDRIVE MD*60A Series
Page 3: ...MOVIDRIVE MD_60A Edition 09 2001 Operating Instructions 1053 2617 EN ...
Page 4: ...SEW EURODRIVE ...
Page 100: ...10 2000 ...
Page 101: ...10 2000 ...