MOVIDRIVE
®
MD_60A Operating Instructions
69
Operating displays
Information
messages
Information messages on the DBG11A (approx. 2 s in duration) or in MOVITOOLS/
SHELL (message which can be acknowledged):
No.
Text DBG11A/SHELL
Description
1
ILLEGAL INDEX
Index addressed via interface is not available.
2
NOT IMPLEMENTED
•
Attempt to execute a non-implemented function.
•
An incorrect communication service has been selected.
•
Manual mode selected via impermissible interface (e.g. fieldbus).
3
READ ONLY VALUE
Attempt to edit a read only value.
4
PARAM. LOCKED
Parameter lock P803 = "ON". Parameter cannot be altered.
5
SETUP ACTIVE
Attempt to alter parameters during active factory setting.
6
VALUE TOO LARGE
Attempt to enter a value which is too large.
7
VALUE TOO SMALL
Attempt to enter a value which is too small.
8
REQ. PCB MISSING
The option pcb required for the selected function is missing.
-
10
ONLY VIA ST1
Manual mode must be completed using X13:ST11/ST12 (RS-485).
11
TERMINAL ONLY
Manual mode must be completed using TERMINAL (DBG11A or
USS21A).
12
NO ACCESS
Access to selected parameter refused.
13
NO CTRLER. INHIBIT
Set terminal DIØØ "/Controller inhibit" = "0" for the selected function.
14
INVALID VALUE
Attempt to enter an invalid value.
--
16
PARAM. NOT SAVED
EEPROM buffer overrun, e.g. due to cyclical write accesses. Parameter is
saved in EEPROM and is not protected against loss following POWER
OFF.