MOVIDRIVE
®
MD_60A Operating Instructions
39
Encoder and resolver connection
Resolver
SEW offers the following pre-fabricated cables for connecting resolvers to
MOVIDRIVE
®
MDS60A:
Terminal/pin
assignment
CM motors: The resolver connections are housed in a plug connection.
DS/DY motors: Depending on the motor type, the resolver connections in the terminal
box are either accommodated on a 10-pin Phoenix terminal strip or in the plug
connection.
Plug connection CM, DS56:
Intercontec, type ASTA021NN00 10 000 5 000
Plug connection DY71 – 112:
Framatome Souriou, type GN-DMS2-12S
The resolver signals have the same numbering on the 10-pin Phoenix terminal strip and
in the plug connections.
Connection
Connect the resolver as follows:
1) Plug connection
2) Terminal strip
If using the pre-fabricated cable with conductor end sleeves, cut off the violet conductor
(VT) of the cable in the motor terminal box.
For motor type
Part number
Fixed routing
Cat track routing
CM71 – 112
with pl. connection
199 214 7
199 215 5
DFS56
with terminal box
198 829 8
198 828 X
with pl. connection
198 927 8
198 928 6
DFY71 – 112
with terminal box
198 829 8
198 828 X
with pl. connection
198 827 1
198 812 3
Terminal/pin
Description
Conductor color in pre-fabricated cable
1
Ref.+
Reference
Pink (PK)
2
Ref.-
Gray (GY)
3
cos+
Cosine signal
Red (RD)
4
cos-
Blue (BU)
5
sin+
Sine signal
Yellow (YE)
6
sin-
Green (GN)
9
TF/TH
Motor protection
White (WH)
10
TF/TH
Brown (BN)
01414BXX
Fig. 39: Connecting the resolver
Ref.+
Ref.-
cos+
cos-
sin+
sin-
N.C.
N.C.
TF/TH
TF/TH
1
2
3
4
5
6
7
8
9
10
1
5
6
9
3
8
2
7
1
6
9
5
4
PK
GY
RD
BU
YE
GN
WH
BN
VT
MOVIDRIVE
X15:
®
max. 100 m (330 ft)
3
4
5
6
9
10
11
12
1
2
7
8
CM, DFS56,
DFY71...112
y
y
✂
1)
2)
Summary of Contents for MOVIDRIVE MD*60A Series
Page 3: ...MOVIDRIVE MD_60A Edition 09 2001 Operating Instructions 1053 2617 EN ...
Page 4: ...SEW EURODRIVE ...
Page 100: ...10 2000 ...
Page 101: ...10 2000 ...