MOVIDRIVE
®
MD_60A Operating Instructions
21
Wiring diagram, basic unit
Control unit connection
03975AEN
Fig. 18: Wiring diagram, control unit
*
Factory setting
**
If the binary inputs are connected to the 24 V
DC
voltage supply X13:8 "VO24", then jumper X13:7 to X13:9
(DCOM to DGND) on MOVIDRIVE
®
.
***
Factory setting: X10:1 (TF1) is jumpered to X10:2 (DGND). The jumper must be removed if a TF or TH is
connected to X10:1 and X10:2.
n11/n21*
n12/n22*
DGND
X14:
X15:
TERMINAL
-10V
+10V
+
-
n1 (0...10V*;+/-10V;
0...20mA;4...20mA)
X11:
X12:
REF1
AI11
AI12
AGND
REF2
1
2
3
4
5
DGND
SC11
SC12
1
2
3
S 11
S 12
X13:
DIØØ
DIØ1
DIØ2
DIØ3
DIØ4
DIØ5
DCOM**
VO24
DGND
ST11
ST12
1
2
3
4
5
6
7
8
9
10
11
RS-485 -
RS-485 +
X10:
K12
(AC-3)
TF1***
DGND
DBØØ
DOØ1-C
DOØ1-NO
DOØ1-NC
DOØ2
VO24
VI24
DGND
1
2
3
4
5
6
7
8
9
10
R11
-10V...+10V 0(4)...20mA
I
X11:AI11/AI12
ON OFF*
1
5
6
9
5
1
9
6
ϑ
24V
OPTION1
OPTION2
CONTR
OL
TERMINAL
CONTROL
E
Q
RS232
RS485
0V5 - +
OPTION2
OPTION1
0
1
2
3
4
5
6
7
8
9
A
b
c
d
E
F
H
t
Depending on option,
connect external 24V supply
(
MOVIDRIVE
electronic data)
→
®
Note! Pin assignment for
connectors X14 and X15.
Not all connectors avail-
able have this pin assignment.
V
Ref. potential for binary signals
Reference X13:DIØØ...DIØ5
Option
slots
Shield
plate
or
shield
ter
minal
Reference potential for binary signals
+24V input
Common relay contact
Ready for operation*
Contact normally closed
Contact normally open
/Brake
/fault*
+24V output
+24V output
Incremental encoder
simulation
or external encoder
connection
(not on MDF)
Encoder (MDV)
or resolver (MDS)
connection
Ref. potential for binary signals
TF/TH input
Reference
Binary outputs
Control unit
Option
DBG11A
Keypad
Option
USS21A
ser.interface
High level
control
Binary
input
Binary
outputs
7-segment display
Operating condition
Inverter not ready
Controller inhibit
No enable
Current at standstill
VFC operation
Speed control
Torque control
Hold control
Factory setting
Limit switch approached
Technology option
Not used
Reference travel IPOS
Flying restart
Not used
Fault indication (flashing)
Manual operation
Timeout active
7-segment display
Ref.potential for analog signals
system bus ref.potential
system bus high
system bus low
Select: I signal
V signal*
system bus terminating resistor
↔
Enable/Rapid stop*
/Controller inhibit
CW/stop*
CCW/stop*
Summary of Contents for MOVIDRIVE MD*60A Series
Page 3: ...MOVIDRIVE MD_60A Edition 09 2001 Operating Instructions 1053 2617 EN ...
Page 4: ...SEW EURODRIVE ...
Page 100: ...10 2000 ...