86
MOVIDRIVE
®
MD_60A Operating Instructions
MOVIDRIVE® MD_60A...-2_3 (230 V units)
Size 3
MOVIDRIVE
®
MD_60A
0110-203-4-0_
0150-203-4-0_
INPUT
Supply voltage
V
in
3
×
200 V
AC
-10 % – 3
×
240 V
AC
+10 %
Supply frequency
f
in
50 Hz – 60 Hz
±
5 %
Rated system current I
in
100 %
(at V
in
= 3
×
230 V
AC
)
125 %
40.0 A
AC
50.0 A
AC
49.0 A
AC
61.0 A
AC
OUTPUT
Output rated power
1)
P
N
(at V
in
= 3
×
200 – 240 V
AC
)
17.1 kVA
21.5 kVA
Output rated current
I
N
(at V
in
= 3
×
230 V
AC
)
42 A
AC
54 A
AC
Current limitation
I
max
Motor and regenerative 150 % I
N
, duration depending on the capacity utilization
Internal current limitation
I
max
= 0 – 150 % can be set in menu (P303 / P313)
Minimum permitted brake
R
BRmin
resistance value (4Q operation)
7.5
Ω
5.6
Ω
Output voltage
V
out
max. V
in
PWM frequency
f
PWM
Adjustable with VFC: 4/8/12/16 kHz (P860 / P861); with CFC/SERVO fixed at 8 kHz
Speed range / resolution
n
A
/
∆
n
A
-5000 – 0 – +5000 rpm / 0.2 rpm across the entire range
GENERAL
Power loss at P
N
P
Vmax
580 W
720 W
Cooling air consumption
180 m
3
/h (108 ft
3
/min)
Weight
15 kg (33.07 lb)
Dimensions
W
×
H
×
D
200
×
465
×
345 mm (7.87
×
18.31
×
13.58 in)
1) MDF and MDV units in VFC operating modes: The performance data apply to f
PWM
= 4 kHz (factory setting).
MDF60A standard type (VFC)
0110-203-4-00
0150-203-4-00
Part number
826 724 3
827 176 3
MDF60A technology type (VFC)
0110-203-4-0T
0150-203-4-0T
Part number
827 369 3
827 370 7
Constant load
Rec. motor power P
Mot
11 kW (15 HP)
15 kW (20 HP)
Variable torque load or constant
load without overload
Rec. motor power P
Mot
15 kW (20 HP)
22 kW (30 HP)
Continuous output current = 125 % I
N
I
D
(at V
in
= 3
×
230 V
AC
and f
PWM
= 4 kHz)
52.5 A
AC
67.5 A
AC
MDV60A standard type (VFC/CFC)
0110-203-4-00
0150-203-4-00
Part number
826 730 8
827 260 3
MDV60A technology type (VFC/CFC)
0110-203-4-0T
0150-203-4-0T
Part number
827 378 2
827 379 0
VFC operating mode
Recommended motor power
→
MDF60A
CFC operating mode
Continuous output current = 100 % I
N
I
D
42 A
AC
54 A
AC
Recommended motor power
→