8
MOVIDRIVE
®
MD_60A Operating Instructions
Unit design, size 1
3.2
Unit design, size 1
MD_60A-5A3 (400/500 V units): 0015 – 0040
MD_60A-2A3 (230 V units): 0015 – 0037
1. X1: Mains connection L1 (1) / L2 (2) / L3 (3), separable
2. X4: DC link connection -U
z
/ +U
z
and PE connection, separable
3. X2: Motor connection U (4) / V (5) / W (6), separable
4. Connection for power shield clamp (not visible)
5. X3: Braking resistor connection R+ (8) / R- (9) and PE connection, separable
6. TERMINAL: Option slot for DBG11A keypad or USS21A serial interface
7. Control pcb on CONTROL option slot
8. X11: Electronics terminal strip (setpoint input AI1 and 10 V reference voltage)
9. Switch S11 (signal type AI1) and switch S12 (system bus terminating resistor)
10.X12: Electronics terminal strip system bus (SBus)
11.7-segment display
12.X10: Electronics terminal strip binary outputs and TF/TH input
13.X13: Electronics terminal strip binary inputs and RS-485 interface
14.Only MDV/MDS, X14: Incremental encoder simulation or external encoder input (9-
pin sub D plug)
15.Only MDV/MDS, X15: Motor encoder input (9-pin sub D socket)
16.OPTION1 and OPTION2: Option slots 1 and 2
17.Connection for electronics shield clamps
01245BXX
Fig. 4: Unit design, MOVIDRIVE
®
size 1
3
4 5
8
9
10
11
13
12
14
15
16
17
1
2
6
7
Summary of Contents for MOVIDRIVE MD*60A Series
Page 3: ...MOVIDRIVE MD_60A Edition 09 2001 Operating Instructions 1053 2617 EN ...
Page 4: ...SEW EURODRIVE ...
Page 100: ...10 2000 ...