24
MOVIDRIVE
®
MD_60A Operating Instructions
Assignment of braking resistors, chokes and filters
400/500 V units, sizes 3 to 5
MOVIDRIVE
®
MD_60A...-503
0150
0220
0300
0370
0450
0550
0750
Size
3
4
5
Braking resistors
Trip current
Part number
BW018-015
I
F
= 4.0 A
RMS
821 684 3
C
C
BW018-035
I
F
= 8.1 A
RMS
821 685 1
C
C
BW018-075
I
F
= 14 A
RMS
821 686 X
C
C
BW915
I
F
= 28 A
RMS
821 260 0
BW012-025
I
F
= 6.1 A
RMS
821 680 0
BW012-050
I
F
= 12 A
RMS
821 681 9
BW012-100
I
F
= 22 A
RMS
821 682 7
BW106
I
F
= 38 A
RMS
821 050 0
BW206
I
F
= 42 A
RMS
821 051 9
Line chokes
Part numbers
ND045-013
Σ
I
system
= 45 A
AC
826 013 3
A
ND085-013
Σ
I
system
= 85 A
AC
826 014 1
B
A
ND1503
Σ
I
system
= 150 A
AC
825 548 2
B
Input filters
Part number
NF035-503
V
max
= 550 V
AC
827 128 3
A
NF048-503
827 117 8
B
A
NF063-503
827 414 2
B
A
NF085-503
827 415 0
B
A
NF115-503
827 416 9
B
A
NF150-503
827 417 7
B
Output chokes
Inside diameter
Part number
HD001
d = 50 mm (1.97 in)
813 325 5
For cable cross sections 1.5 – 16 mm
2
(AWG 16 – 6)
HD003
d = 88 mm (4.46 in)
813 558 4
For cable cross sections > 16 mm
2
(AWG 6)
Output filters (only in VFC mode)
Part number
HF033-403
825 785 X
A
B / D
A / D
HF047-403
825 786 8
B
A
HF450-503
826 948 3
B
E
D
D
A
In rated operation (100 %)
B
With variable torque load in VFC mode (125 %)
C
Connect two braking resistors in parallel and set twice the trip current on F16 (2
×
I
F
)
D
Connect two output filters in parallel
E
In rated operation (100 %): One output filter
With variable torque load (125 %): Connect two output filters in parallel
Summary of Contents for MOVIDRIVE MD*60A Series
Page 3: ...MOVIDRIVE MD_60A Edition 09 2001 Operating Instructions 1053 2617 EN ...
Page 4: ...SEW EURODRIVE ...
Page 100: ...10 2000 ...
Page 101: ...10 2000 ...