Preliminary work and resources
5.2
Preliminary work and resources
•
Check installation.
•
Take suitable measures to prevent the motor starting up inadvertently, for example
by removing the electronics terminal block X13:. Furthermore, additional safety
precautions must be taken depending on the application in order to avoid
endangering people and machinery.
•
For startup with the DBG11A keypad:
Connect the DBG11A keypad to the TERMINAL option slot.
•
For startup with a PC and MOVITOOLS:
Connect the USS21A option to the TERMINAL option slot and use an interface cable
(RS-232) to connect it to the PC. MOVIDRIVE
®
and the PC must be de-energized
when you do this, otherwise undefined states may be adopted. Then switch on both
units. Install MOVITOOLS on the PC if you have not already done so. Start the
program.
•
Switch on the power system and, if necessary, the 24 V supply.
If you are using the DBG11A keypad, the following message appears for about 13 s:
•
Undertake the correct preliminary parameter setting (e.g. factory setting).
•
Check the terminal assignment which has been set (
→
P60_ / P61_).
SELFTEST
MOVIDRIVE
Startup automatically changes a group of parameter values. The parameter
description P700 "Operating modes" explains which parameters are affected by this.
Refer to the MOVIDRIVE® system manual, Sec. 4 "Parameters", for the parameter
description.