H.11
Date Code 20081022
Instruction Manual
SEL-787 Relay
Synchrophasors
C37.118 Synchrophasor Protocol
See
for complete command options, and error
messages.
=>
MET PM <Enter>
SEL-787 Date: 02/05/2008 Time: 17:22:07
TRNSFRMR RELAY Time Source: External
Time Quality Maximum time synchronization error: 0.000 (ms) TSOK = 1
Synchrophasors
Phase Voltages Pos. Sequence Voltage
VA VB VC V1
MAG (kV) 134.14 131.64 128.60 131.45
ANG (DEG) 129.57 10.57 -111.89 129.47
Phase Currents Pos. Sequence Current
IAW1 IBW1 ICW1 I1W1
MAG (A) 365.26 359.22 379.91 367.91
ANG (DEG) 114.03 -2.46 -120.25 117.03
IAW2 IBW2 ICW2 I1W2
MAG (A) 617.05 587.00 599.40 600.93
ANG (DEG) 136.34 13.93 -106.93 134.65
FREQ (Hz) 60.00
Rate-of-change of FREQ (Hz/s) 0.00
Digitals
SV24 SV23 SV22 SV21 SV20 SV19 SV18 SV17
0 0 0 1 0 0 1 0
SV32 SV31 SV30 SV29 SV28 SV27 SV26 SV25
0 1 0 0 0 1 0 0
Analogs
MV29 2.300 MV30 0.150 MV31 17.400 MV32 -9.230
=>
Figure H.4
Sample MET PM Command Response
C37.118 Synchrophasor Protocol
The SEL-787 complies with IEEE C37.118, Standard for Synchrophasors for
Power Systems. The protocol is available on serial ports 2, 3, 4, and F by
setting the corresponding Port setting PROTO := PMU.
This subsection does not cover the details of the protocol, but highlights some
of the important features and options that are available.
Settings Affect
Message Contents
The SEL-787 allows several options for transmitting synchrophasor data.
These are controlled by Global settings described in
. You can select how often to transmit the
synchrophasor messages (MRATE) and which synchrophasors to transmit
(PHDATAV, PHDATAI, and PHCURR). The SEL-787 automatically includes
the frequency and rate-of-change-of-frequency in the synchrophasor
messages.
The relay can include up to four user-programmable analog values in the
synchrophasor message, as controlled by Global setting NUMANA, and 0 or
16 digital status values, as controlled by Global setting NUMDSW.
The SEL-787 always includes the results of four synchrophasor trigger reason
SEL
OGIC
equations TREA1, TREA2, TREA3, and TREA4, and the trigger
SEL
OGIC
equation result PMTRIG, in the synchrophasor message.
Summary of Contents for SEL-787
Page 1: ...20081022 SEL 787 Transformer Protection Relay Instruction Manual PM787 01 NB ...
Page 6: ...This page intentionally left blank ...
Page 12: ...This page intentionally left blank ...
Page 18: ...This page intentionally left blank ...
Page 78: ...This page intentionally left blank ...
Page 206: ...This page intentionally left blank ...
Page 280: ...This page intentionally left blank ...
Page 334: ...This page intentionally left blank ...
Page 376: ...This page intentionally left blank ...
Page 388: ...This page intentionally left blank ...
Page 474: ...This page intentionally left blank ...
Page 508: ...This page intentionally left blank ...