Synergy Q/MD Engineering Manual (v9.1 MD)
Preliminary Cabling and Video Installation • 4–5
Remote Aux Panel Interconnection — Synergy 2 and 2.5 Control Panels
Use the following procedure to install the control cables between the control panel and each remote
Aux panel:
1. Ensure that you have the correct
6-pin
shielded Telco cable, with a
6-pin RJ-12
connector at each end.
2. Connect a 6-pin shielded Telco cable (of the supplied or custom length) between the
AUX 1
connector on the control panel and the connector labelled
MAIN
on the rear of
the
first
Aux panel in line.
3. To daisy-chain additional Aux panels (up to
8
), connect a 6-pin shielded Telco cable
between the Aux panel connector labeled
ECHO
and the connector labeled
MAIN
on
the
next
Aux panel in line.
4. Repeat step 3 for all additional Aux panels in the
AUX 1
daisy-chain (up to the
maximum of
8
panels per chain).
This completes the procedure for installing the control cables of a Remote Aux Panel to the Synergy
Q/MD control panel. Repeat this procedure to connect additional Remote Aux Panels to the
AUX 2
port.
Synergy 1 Q/MD Remote Aux Panel Cabling
Unlike the
Synergy 1.5, 2
and
2.5 Q/MD
Switchers
, the
Synergy 1 Q/MD
does not have a dedicated
AUX
port. Instead, the provided
RJ-12 to DB9 Aux Adapter
must be installed and setup in the
Remote 5
port on the rear of the control panel in order to connect a
Remote Aux Panel
to the
switcher.
Synergy 1 Q/MD Remote 5 Port Setup
Use the following procedure to assign the Remote 5 port on the rear of the
Synergy 1 Q/MD
control
panel to an Aux port:
1. Navigate to the
Communications Menu 1-2
as follows:
•
Press
HOME
B
MORE
B
Setup
B
Installation
B
Communications
.
Remote Aux Panel
To connector J5 on
the next Aux Panel
in the chain, or no
connection if the last
panel in the chain.
Remote Aux Panel
8
1
2
3
4
7
6
5
4
3
2
1
REMOTE
TALLY
2
1
FRAME
AUX
Synergy Control Panel
To connector J5 on
the next Aux Panel
in the chain, or no
connection if the last
panel in the chain.
Summary of Contents for Synergy MD
Page 1: ...Ross Video Limited Synergy Q MD Engineering Manual Volume I Software Issue 9 1 MD ...
Page 10: ......
Page 18: ...viii Contents Synergy Q MD Engineering Manual v9 1 MD ...
Page 46: ...1 28 Introduction Synergy Q MD Engineering Manual v9 1 MD ...
Page 204: ...7 34 BNC Configuration and Check Synergy Q MD Engineering Manual v9 1 MD ...
Page 302: ...10 56 Custom Controls Synergy Q MD Engineering Manual v9 1 MD ...
Page 366: ...13 16 SmartConversion Synergy Q MD Engineering Manual v9 1 MD ...
Page 370: ...GL 4 Glossary of Terms Synergy Q MD Engineering Manual v9 1 MD ...