4-41
4 Adjustment
4
4
5
FORMULA
CA = CL - ML
ML
x 100
Calculate the amount to be calibrated with the formula
shown at the right figure.
1. CA = Calibrating Amount
2. CL = Commanded Length (=400mm)
3. ML = Measured Length
Select the [SETTING] menu under the [CALIB.
DEFAULT] menu and change the amount to be
calibrated with [
] and [
] keys.
Press the [ENTER] key to save the setting.
Parameters can be entered with an increment
of 0.02%.
(MAX. +2.00% ~ MIN. -2.00%)
CALIB.DEFAULT
SETTING
SETTING
+0.00% +0.14%
SERVICE MENU
CALIB.DEFAULT