![Roland SP-300 Service Manual Book Download Page 21](http://html.mh-extra.com/html/roland/sp-300/sp-300_service-manual-book_1481315021.webp)
• Cleaning Wiper
When Cleaning is performed, Heads will be rubbed or
wiped by the Cleaning Wiper located at the left side of the
Capping Unit to remove foreign substances on the Heads.
1. Wiping
- soft
It is done at the rubber
side of the cleaning wiper.
2. Rubbing
- strong
It is done at the felt side
of the cleaning wiper.
Head Cleaning
Head Cleaning
Rubber side
Felt side
Summary of Contents for SP-300
Page 128: ...2 Electrical Section 2 2 2 2 2 MAIN BOARD DIP SW DIP SW bit 1 bit 8 Always OFF ...
Page 134: ...2 Electrical Section 2 8 2 2 3 SERVO BOARD ...
Page 135: ...2 Electrical Section 2 9 2 ...
Page 140: ...2 Electrical Section 2 14 2 2 4 HEATER BOARD ...
Page 189: ...3 Replacement of Main Parts 3 42 3 9 Carry out the LINEAR ENCODER SETUP ...