3 Replacement of Main Parts
3-34
3
CLOCK CHECK B
0y00d00h00m00s
CLOCK CHECK
CLEAR BAT FLAG
SERVICE MENU
CLOCK CHECK
[ENTER]
2
Remove the BATTERY on the MAIN BOARD by
pushing it down and tilting towards right.
1
SOCKET
MAIN BOARD
2
3
Replace the BATTERY with new one.
SOCKET
BATTERY
MAIN BOARD
Be careful with the direction of the BATTERY.
4
Clear the BATTERY FLAG from the [CLOCK CHECK]
menu in the SERVICE MODE.
5
Dispose the BATTERY.
FOLLOWING MAY CAUSE EXPLOSION OF BATTERY.
RECHARGE, SHORT-CIRCUIT, DISASSEMBLY, HEATING,
PUTTING INTO FIRE.
DON'T PUT BATTERY WITH OTHER METAL OR BATTERY.
DISPOSE BATTERY WITHOUT INSULATION.
Summary of Contents for SP-300
Page 128: ...2 Electrical Section 2 2 2 2 2 MAIN BOARD DIP SW DIP SW bit 1 bit 8 Always OFF ...
Page 134: ...2 Electrical Section 2 8 2 2 3 SERVO BOARD ...
Page 135: ...2 Electrical Section 2 9 2 ...
Page 140: ...2 Electrical Section 2 14 2 2 4 HEATER BOARD ...
Page 189: ...3 Replacement of Main Parts 3 42 3 9 Carry out the LINEAR ENCODER SETUP ...