4-13
4 Adjustment
4
Turn on the sub power switch while
pressing [ ] key.
Service Report can be printed on the A4
size media.
The printing will be performed in Black.
* Please print the [History Report] from
the Service Mode.
The machine becomes on by turning the sub power switch
while pressing [ ], [ ] and [ENTER] keys.
Initialize can be performed by pressing the [ENTER] key.
It can also be canceled by pressing the [POWER] key.
The power will be off automatically when initialize is completed.
It is necessary to do the LIMIT POSITION INITIALIZE after this operation.
The error message [SERVICE CALL 0101] will appear
if you don't setup the LIMIT POSITION.
SYSTEM PARAMETER INITIALIZE
[ ] , [ ] , [ ENTER ] + POWER ON
INITIALIZE ALL
SYS.PARAMETER
INITIALIZE
COMPLETED
DISPLAYED LANGUAGE
SERVICE REPORT_PRINTING
[ ] + POWER ON
SERVICE REPORT
SETUP SHEET
[ MENU ] + POWER ON
Roland SP-300
Ver.1.00
MENU LANGUAGE
ENGLISH
LENGTH UNIT
mm INCH
TEMP. UNIT
C F
ENGLISH/JAPANESE
Other Factory Mode
Summary of Contents for SP-300
Page 128: ...2 Electrical Section 2 2 2 2 2 MAIN BOARD DIP SW DIP SW bit 1 bit 8 Always OFF ...
Page 134: ...2 Electrical Section 2 8 2 2 3 SERVO BOARD ...
Page 135: ...2 Electrical Section 2 9 2 ...
Page 140: ...2 Electrical Section 2 14 2 2 4 HEATER BOARD ...
Page 189: ...3 Replacement of Main Parts 3 42 3 9 Carry out the LINEAR ENCODER SETUP ...