3 Replacement of Main Parts
3-13
3
14
13
[MENU] key
[ ], [ ], [ ] + POWER ON
MENU
SERVICE MENU
[ ]
[ ]
[ENTER]
SERVICE MENU
CAP&WIPER CTRL
CAP&WIPER CTRL
CAP
CAP
OPEN
15
Connect the tube of the CAP TOP to the tube of the
PUMP using the JOINT TUBE.
Turn on the MAIN POWER SW, then turn on the SUB
POWER SW while pressing the Left, Right and Down
keys to enter the SERVICE MODE.
Select [CAP&WIPER CTRL] > [CAP] > [OPEN], and
press the [ENTER] key. The capping unit moves down.
16
JOINT TUBE
Fix the PUMP COVER.
PUMP COVER
Make sure to set the direction of the TUBE
HOLDER so that open side faces front and
rear.
TUBE HOLDER
Summary of Contents for SP-300
Page 128: ...2 Electrical Section 2 2 2 2 2 MAIN BOARD DIP SW DIP SW bit 1 bit 8 Always OFF ...
Page 134: ...2 Electrical Section 2 8 2 2 3 SERVO BOARD ...
Page 135: ...2 Electrical Section 2 9 2 ...
Page 140: ...2 Electrical Section 2 14 2 2 4 HEATER BOARD ...