4-24
4 Adjustment
4
21
[BIDIRECTION ADJUSTMENT]
Select [BI-DIR.DEFAULT TEST PRINT] in the [HEAD
ADJUST] menu and press the [ENTER] key.
[ ]
SERVICE MENU
HEAD ADJUST
HEAD ADJUST
BI-DIR.DEFAULT
BI-DIR.DEFAULT
TEST PRINT
[ ]
[ ]
22
Following TEST PATTERN will be printed.
Find the position where the upper block matches the lower block and check the number.
In case of having problem deciding the number, the number between the 2 numbers can be selected.
The number with is the current setting.
+17
+16
+15
+14
+13
+12
+11
+10
+9
0
+18 +19 +20 +21
+40
H2
H1
DT1
+17
+16
+15
+14
+13
+12
+11
+10
+9
0
+18 +19 +20 +21
+40
H2
H1
DT3
23
Select [DT1] and [DT3] and in the [BI-DIR. DEFAULT]
menu and enter the parameters checked at 22
with [ ] and [ ] keys.
Press the [ENTER] key to save the settings.
Parameters can be entered
with an increment of 0.5.
HEAD ADJUST
BI-DIR.DEFAULT
BI-DIR.DEFAULT
TEST PRINT
H1 H2
2 3
BI-DIR.DEFAULT
ADJUST DT1
BI-DIR.DEFAULT
ADJUST DT3
H1 H2
2 3
Summary of Contents for SP-300
Page 128: ...2 Electrical Section 2 2 2 2 2 MAIN BOARD DIP SW DIP SW bit 1 bit 8 Always OFF ...
Page 134: ...2 Electrical Section 2 8 2 2 3 SERVO BOARD ...
Page 135: ...2 Electrical Section 2 9 2 ...
Page 140: ...2 Electrical Section 2 14 2 2 4 HEATER BOARD ...
Page 189: ...3 Replacement of Main Parts 3 42 3 9 Carry out the LINEAR ENCODER SETUP ...