4-33
4 Adjustment
4
5
Adjust the VR on the CARRIAGE BOARD so that the
"MAX" voltage displayed on the LCD will be 2.5 +/- 0.2V.
6
Perform [OUTLEVEL CHECK] again and make sure
that the voltage is correct value.
If it is out of range, adjust it again.
VR
4
The voltage displayed in the LCD decreases
for some degree due to the ink drying.
MIN 1.9V MAX 2.6V
[ 2.4V ]
Select [OUTLEVEL CHECK] under the [CROPMARK
SENS] menu.
Press the [ENTER] key, and the Crop Mark will be
printed. Then the TOOL CARRIAGE moves on the
Crop Mark automatically.
MIN 1.9V MAX 2.6V
[ 2.4V ]
SERVICE MENU
CROPMARK SENS
CROPMARK SENS
OUTLEVEL CHECK
[ ]