4-7
4 Adjustment
4
SERVICE MENU
SYSTEM SWITCH
SYSTEM SWITCH
PAGE1: 00000000
SYSTEM SWITCH
PAGE8: 00000000
This menu is for changing the functions of the machine. Normally, it is not necessary to change any switches.
Each bit can be selected with [ ] and [ ] keys and it can be changed with [ ] and [ ] keys.
There are 8 pages of 8 bit System Switch.
bit# [87654321]
SERVICE MENU
TIME OUT
TIME OUT
10 sec 10 sec
This menu is used for setting the Time Out.
If the data transmission from the host stops for a set time, the machine recognizes that 1 printing has been
done. Default : NONE
SERVICE MENU
MAINTE. MSG.
MAINTE. MSG.
NONE 100 hours
This menu is used for setting the Maintenance time.
If the printing time reaches the set time, the Maintenance message appears.
SERVICE MENU
PORT CHECK
DETECTING...
00: 0B
USB
5A: 1024B
Waiting for Data Input
Data Input from the USB Port
This menu is used for checking the Data Input from the USB port.
The Check Sum and the size of the input data will be displayed on the bottom row.
Check Sum will be indicated on the left side and the size of the input data will be indicated on the right
side. The Check Sum and the size of the input data will be cleared when pressing the [ENTER] key.
DRYER
0 -3
SERVICE MENU
HEATER ADJUST
PRINT HEATER
0 -3
HEATER ADJUST
PRINT HEATER
-5~+5
NOZZLE MASK
DRYER
-5~+5
This menu is used for setting the offset value of print heater
The heater is controlled based on the offset temperature.
SERVICE MENU
HEAT TIMEOUT
HEAT TIMEOUT
OFF 10min
OFF,10~30min
This menu is used for setting time to display a check message during temperature control of the print heater at the time of a printing start.
When temperature control is not completed even if time passes, and printing cannot be started,
The message of "Temperature has not gone up. Is control continued? is displayed.
SERVICE MENU
PREHEAT TEMP.
PREHEAT TEMP.
35 C 35 C
OFF, 20~40 C
This menu is used for setting the preheat temperature of the print heater.
In this menu, the temperature of [PREHEAT] under the [PREHEATING] in the USER MENU can be set.
The range which user can set by [HEATER CONFIG] becomes more than the temperature set in this menu.
Bit
Contents
Settings
Default Setting
PAGE1: Bit 1 Front Cover Sensor
0 : Standard 1: Always closed status
0
PAGE1: Bit 2 I/S Cover Sensor
0 : Standard 1: Always closed status
0
PAGE1: Bit 5 Nozzle Mask Menu
0 : Disable 1: Enable
0
PAGE1: Bit 7 Presetting for Offset Value Menu
0 : Disable 1: Enable
1
PAGE2: Bit 1 Cutting Heavy Mode
0 : Normal 1: Cutting with Heavy Mode
0
PAGE2: Bit 5 Cartridge exchange during printing
0 : Disable 1: Enable
* Printing doesn't stop for 5 seconds even if ink cartridge is removed.
0
PAGE3: Bit 1 Heater support
0 : Disable 1: Enable
1
PAGE3: Bit 2 Heater -related setting for printing test patterns
0 : Reflect 1: No Reflect
* When 1 is set, setting of [FULL WIDTH] and [SCAN INTERVAL]
in the USER MENU is reflected on the test pattern.
0
PAGE6: Bit 8 Heater operation in the service mode
0 : Disable 1: Enable
* Heater becomes on even if the machine is in the service mode.
0
Summary of Contents for SP-300
Page 128: ...2 Electrical Section 2 2 2 2 2 MAIN BOARD DIP SW DIP SW bit 1 bit 8 Always OFF ...
Page 134: ...2 Electrical Section 2 8 2 2 3 SERVO BOARD ...
Page 135: ...2 Electrical Section 2 9 2 ...
Page 140: ...2 Electrical Section 2 14 2 2 4 HEATER BOARD ...
Page 189: ...3 Replacement of Main Parts 3 42 3 9 Carry out the LINEAR ENCODER SETUP ...