- 3.41 -
xx = it indicates the motor which generated the error
1-32 Seeding disc
1-32
33-40 Fertilizer spreader
1-8
49-56 Micro-granulator A
1-8
57-64 Micro-granulator B
1-8
Error
code
Message
Solution
battery voltage
1xx12
Find rotor position error
Not active on customer release
1xx13
Safety switch open
Close lid or seeding element cover. Check
security switch
1xx14
Pwm control volt
Cycle power of the system from battery
disconnect. Contact supplier if not solved
1xx15
Position control error
Cycle power of the system from battery
disconnect. Contact supplier if not solved
1xx16
Blocked Seeding disk
Check seeding disk for stuck seeds or
distributor of stuck/blocking product.
1xx17
Low voltage
Check PTO speed to be according to
specifications. Check alternator voltage.
Check battery connection and fuses
1xx26
Seed selector
Verify that there isn't any material (seeds,
dust, etc.) preventing the correct movement
of seed selector. Verify that seed selector
cam is fitted properly on seed selector motor
shaft. From the menu\Diagnostic\Test\Seed
Selector, press "Homing" button to perform
the homing procedure
1xx30
Generic
Recoverable emergency
1xx80
High number of doublets
Check at every single turn, adjust the seed
selector position to a lower set value.
1xx81
High number of missings
Check at every single turn, adjust the seed
selector position to a higher set value.
1xx83
High number of missings
Quick check less than one turn, check the
pressure rate and the seeds selector position
1xx84
Prefill not completed
Verify that vacuum is correct and seeds are
present in the hopper
1xx85
High number of doublets
Long period alarm, adjust the seed selector
position to a lower set value.
1xx86
High number of missings
Long period alarm, adjust the seeds selector
position to a higher set value, for example to
detect a plugged disk hole.
1-1xx14 Pwm control volt
Cycle power of the system from battery
disconnect.
Contact supplier if not solved.
1-1xx15 Position control error
Cycle power of the system from battery
disconnect.
Contact supplier if not solved.
Summary of Contents for PCS 200
Page 1: ...PCS 200 Installation Operation Maintenance ORIGINAL INSTRUCTIONS ...
Page 4: ......
Page 33: ...Installation PCS 200 Kit 2 13 Figure 2 Wiring diagram of the system without alternator ...
Page 35: ...Installation PCS 200 Kit 2 15 Figure 2 14 ECU wiring diagram ...
Page 41: ...Installation PCS 200 Kit 2 21 This page is intentionally left blank ...
Page 102: ...User Manual PCS 200 Kit 3 61 This page is intentionally left blank ...
Page 105: ...Maintenance and Troubleshooting PCS 200 Kit 4 3 4 4 SPARE PARTS ...
Page 111: ...Maintenance and Troubleshooting PCS 200 Kit 4 9 This page is intentionally left blank ...