User Manual
- 3.10 -
PCS 200 Kit
two index pulses)
5
It allows to force the motors addressing session
Seeding discs
Tab
Field
Values range
Description
1
1
…
32
Number of seeding elements
2
-10000 ... 10000
Reduction gear ratio multiplied by 100 (for example:
reduction gear 28.89: 1
2889)
The minus sign indicates rotation direction opposite to the
standard one.
3
0
–
4
Off: The disc prefill is not carried out
Timed: The prefill will be carried out without using the
information from the seeding sensor, for ex. the disc
rotates of about 270° before stopping.
1
…
5: Number of seeds which should be detected in order
to end the disc Prefill phase.
4
0
–
100%
The percentage indicated a fraction of the angle between
two holes of the seeding disc (for ex. 50% indicates half of
the angle between two holes).
Each time a seed falls, an angular window is taken into
account corresponding to the indicated percentage fraction.
If the sensor detects other seeds after the first one, these
will be considered as
“
doublets
”
inside the angular window.
5
…
.
It enables the hopper level sensor (if present)
1
2
3
4
5
6
Summary of Contents for PCS 200
Page 1: ...PCS 200 Installation Operation Maintenance ORIGINAL INSTRUCTIONS ...
Page 4: ......
Page 33: ...Installation PCS 200 Kit 2 13 Figure 2 Wiring diagram of the system without alternator ...
Page 35: ...Installation PCS 200 Kit 2 15 Figure 2 14 ECU wiring diagram ...
Page 41: ...Installation PCS 200 Kit 2 21 This page is intentionally left blank ...
Page 102: ...User Manual PCS 200 Kit 3 61 This page is intentionally left blank ...
Page 105: ...Maintenance and Troubleshooting PCS 200 Kit 4 3 4 4 SPARE PARTS ...
Page 111: ...Maintenance and Troubleshooting PCS 200 Kit 4 9 This page is intentionally left blank ...