Field
Values range
Description
1
3
–
101
Number of holes on the seeding disc
2
2
–
100 cm or
1 - 100000
seeds/ha
Seeding distance expressed in cm or, as an alternative,
investment value expressed in seeds/ha.
3
-
These numeric fields represent the conversion between seeding
distance and investment.
4
Off,1
–
4
Doublets/missings sensitivity
(Off = disabled control
1 = min. sensitivity
…
4 = max. sensitivity)
5
Off,1
–
4
Sensitivity to the deviation from the theoretical investment
(Off = disabled control
1 = min. sensitivity
…
4 = max. sensitivity)
6
0
–
16 km/h
Maximum speed limit imposed only by the seeding discs settings.
Warning!
This is not necessarily the most binding limitation: it is
possible that the fertilizer spreaders and/or microgranulators
settings impose stricter limitations to the maximum seeding
speed.
7
1 - 32
It shows the number of effectively used rows for the seeding and
the calculation of the sown hectares. It is calculated as the
number of seeding discs minus the number of disabled elements
(see chapter
Seeding disks disabling
).
8
On/off
Automatic recovery of the rows which have been switched off by
the manual tramline at the end of the field. This operation is done
during the transition phase between lifted/lowered machine.
1
2
4
5
3
6
7
8
Summary of Contents for PCS 200
Page 1: ...PCS 200 Installation Operation Maintenance ORIGINAL INSTRUCTIONS ...
Page 4: ......
Page 33: ...Installation PCS 200 Kit 2 13 Figure 2 Wiring diagram of the system without alternator ...
Page 35: ...Installation PCS 200 Kit 2 15 Figure 2 14 ECU wiring diagram ...
Page 41: ...Installation PCS 200 Kit 2 21 This page is intentionally left blank ...
Page 102: ...User Manual PCS 200 Kit 3 61 This page is intentionally left blank ...
Page 105: ...Maintenance and Troubleshooting PCS 200 Kit 4 3 4 4 SPARE PARTS ...
Page 111: ...Maintenance and Troubleshooting PCS 200 Kit 4 9 This page is intentionally left blank ...