Installation
- 2.6 -
PCS 200 Kit
2.5
ALTERNATOR
The alternator is used to create a supply source independent from the tractor one.
The machine manufacturer should provide the mechanical solution to fasten the
alternator and connect it by means of a suitable transmission belt and an overdrive,
from the tractor PTO.
For machine configurations up to 12 rows we suggest an Iskra alternator type AAN
150A 14V. Nominal current 150A.
(Reference drawing: ott_11204254_50034_pre_aan8166_14v_150a_mtz.pdf)
2.5.1 Pulleys and rotation direction
The pulleys (PTO and alternator side) should be chosen in order to reach a speed of
3000 rpm, at the PTO nominal speed.
The shaft should rotate clockwise when observing the pulley front side from
the alternator.
Figure 2-6 - Alternator rotation direction