Installation
PCS 200 Kit
- 2.7 -
2.5.2 Absorbed mechanical power and radial loads
At this speed the absorption rate can be about 4kW in the worst case (= cold
alternator) (Cold Po[kW] curve).
The belt and its tensioning should be sized according to the given power.
The tensioning system is typically obtained using one of the two fastening elements
as a pin and the other one as a moving element to adjust the chain tensioning.
The radial loads created by the belt on the alternator shaft, should be checked with
the alternators’ manufacturer.
A reference value not to be exceeded in order to grant the requested lifetime is
1000N.
Rotation speed of the alternator axis
3000 rpm
Rotation direction
Clockwise (see
Figure 2-6 - Alternator rotation direction
)
Power required by PTO
4 kW
Radial load on the alternator axis
1000N
Table 2-1 - Main information for the alternator integration
Figure 2-7 - Characteristic power curves for the alternator
Summary of Contents for PCS 200
Page 1: ...PCS 200 Installation Operation Maintenance ORIGINAL INSTRUCTIONS ...
Page 4: ......
Page 33: ...Installation PCS 200 Kit 2 13 Figure 2 Wiring diagram of the system without alternator ...
Page 35: ...Installation PCS 200 Kit 2 15 Figure 2 14 ECU wiring diagram ...
Page 41: ...Installation PCS 200 Kit 2 21 This page is intentionally left blank ...
Page 102: ...User Manual PCS 200 Kit 3 61 This page is intentionally left blank ...
Page 105: ...Maintenance and Troubleshooting PCS 200 Kit 4 3 4 4 SPARE PARTS ...
Page 111: ...Maintenance and Troubleshooting PCS 200 Kit 4 9 This page is intentionally left blank ...