User Manual
PCS 200 Kit
- 3.39 -
Error
code
Message
Solution
1060
Error overflow 1
Contact technical support
1061
Error overflow 2
Contact technical support
1062
Internal error
Contact technical support
1063
Log checksum failure
Contact technical support
1470
Connection timeout
Check CAN cable connection between ECU and HMI
1471
Invalid protocol version debug
Not active on customer release
1472
Invalid protocol version
SW version of ECU and HMI are not compatible.
Make sure that latest SW updates have been
correctly downloaded to ECU and HMI. Note
1480
Missing connection ECU / MD
Check CAN cable connection between ECU and
DMD. Check supply cable to ECU. Check battery
voltage
1481
Connection timeout ECU / MD
Check connection between ECU and DMD or
between DMD
1490
Initialize timeout (%1)
Contact technical support
1550
Connection timeout
Check connection between ECU and remote
terminal
1600
Machine taxing position
Machine in transport position (lifted) If this is
happening when machine is supposed to be
seeding, check cabling and machine position sensor
1610
Pressure sensor failure
Check connection of pressure sensor
1611
Pressure out of range
Adjust PTO speed so that vacuum pressure is within
the range
1612
Pressure range min > max
Check min and max limit setting of pressure so that
min < max
1701
MD protocol error
Update DMD with latest SW and check that
addressing procedure has been correctly completed
1703
Configuration and setup parameters lost
Machine configuration parameters have been reset
to default. Check and correct configuration
parameters where applicable
1801
Invalid configuration or MD address
Check MD fuses. Addressing procedure of DMD has
to be performed
2000
Data checksum
Contact technical support
2001
Invalid checksum
Contact technical support
2003
Debug mode
Not active on customer release
2007
Event log failure
Contact technical support
2008
FRAM checksum error
Contact technical support
2009
FSM queue overflow
Contact technical support
2100
Cpu watch dog
Contact technical support
2101
Software trap
Contact technical support
2200
Speed sensor failure
Check speed sensor cabling
2500
Group A parameters mismatch
Not possible to set that combination of parameters
(number of disk holes, seeding distance)
2501
Group B parameters mismatch
Not possible to set that combination of parameters
(number of disk holes, seeding distance)
Summary of Contents for PCS 200
Page 1: ...PCS 200 Installation Operation Maintenance ORIGINAL INSTRUCTIONS ...
Page 4: ......
Page 33: ...Installation PCS 200 Kit 2 13 Figure 2 Wiring diagram of the system without alternator ...
Page 35: ...Installation PCS 200 Kit 2 15 Figure 2 14 ECU wiring diagram ...
Page 41: ...Installation PCS 200 Kit 2 21 This page is intentionally left blank ...
Page 102: ...User Manual PCS 200 Kit 3 61 This page is intentionally left blank ...
Page 105: ...Maintenance and Troubleshooting PCS 200 Kit 4 3 4 4 SPARE PARTS ...
Page 111: ...Maintenance and Troubleshooting PCS 200 Kit 4 9 This page is intentionally left blank ...