Locating the Concentrate Feeder
Adjusting the dosing flap
:
Remove the cover next to the feeding bowl.
Dosing flap
Adjustable plate
with reed switch
:
Only loosen the upper screw on adjustable plate with reed switch (refer to above
drawing).
:
Move the adjustable plate up-- or downward to change the position of the dosing flap.
Upward
: less fodder in the bowl. Take care that the signal empty is displayed (LED
must light).
Downward
: more fodder in the bowl. If after approx. 5 -- 6 seconds (= 5 rotations of the
shaft) the signal empty has not disappeared, the display shows the error message
„Idle Shaft“.
The LED lights when the dosing flap signals „empty“.
:
Use a Test--Responder to check once again the quantity of concentrate dispensed.
:
After regulation of the dosing flap, fasten the screw on the adjustable plate and fix the
cover.