141
Cleaning
Press Arrow Up or Arrow Down to select submenu
„Settings“.
Press Arrow Right to move to the next screen.
Press Arrow Right to go to the next screen.
Enter „no“ if the heat exchanger must not be cleaned automa-
tically. Press ENTER to confirm the input.
If you select „yes“, press Arrow Right to move to the next
screen. Press ENTER.
Enter the frequency of heat exchanger cleaning. Press ENTER
to confirm the input.
Press Arrow Right to move to the next screen. Press ENTER.
Enter the time when heat exchanger cleaning has to be carried
out, e.g. at 2:00 a.m. and 2:00 p.m. (14:00). Press ENTER to
confirm the input.
If you enter two cleaning times, make sure that the lag between the first and the second clea-
ning process (at the lower right of the screen) is at least 1 hour. Otherwise, the automatic
feeder will carry out only
one
cleaning process.
The cleaning process takes place as soon as the milk in the stainless steel coil of the heat
exchanger has been fed to the animals. When cleaning time has come and there is still milk
in the coil, the automatic feeder tries to feed the milk for one hour. As the coil is filled with
the water needed for cleaning, it may happen that the first two drinking portions for an an-
imal being entitled e.g. to 2 liters of milk consist of milk and the following of milk powder
+ water. If the animal does not drink the milk, the automatic feeder carries out automatic
cleaning 1 hour after the entered time, at the latest. The milk is then pressed out of the coil
into the mixer jar by the incoming water and subsequently pumped out via the mixer outlet
valve.
15.5.2 Cleaning Settings Mixer
In Menu „Cleaning Settings, Mixer“ you can enter the frequency of automatic mixer clea-
ning per day. You can enter up to 9 times per day. We recommend to clean the mixer 3 times
per day, i.e. every 8 hours. If the automatic heat exchanger cleaning is active, 3 hours before
and 3 hours after heat exchanger cleaning, the mixer will not be cleaned regardless of the
number of entered cleaning processes. After the cleaning process has been completed, the
liquid in the mixer jar is drained off automatically via the suction hoses resp. the teat.
Turn the program switch to 2 = rinsing.
cleaning
settings^
➔
cleaning settings
heat exchanger^
➔
clean HE
automatically
yes
➔
clean HE
automatically
no
➔
clean HE
2 times / day
➔
clean HE at
10:00 and 22:00 h
clean HE at
2:00 and 14:00 h