50
Connection Test towards the Concentrate Feeder
8.4 Connection Test towards the Concentrate Feeder
Carry out a connection test after expert installation of the cable that connects the Stand
Alone to the concentrate feeders.
Turn program switch to 10 = keyboard.
Enter 49 and press ENTER to confirm the input.
Press Arrow Right to go to the next screen.
Select „yes“ and press ENTER to confirm the input.
Move to the next screen.
Select „yes“ and press ENTER to confirm the input.
If the connection e.g. to the silos 1 & 2 is o.k., the display
shows:
In case of connection fault, check the connecting cable to-
wards the concentrate feeder as well as the power supply of
the stations.
See wiring diagram
.
If necessary, carry out an interface test. S
ee chapter 8.3.5,
page 46, „Setup, Carrying out an Interface Test“
.
49#connection test
➔
49# silo 1&2 test
connection
no
➔
49# silo 1&2 test
connection
yes
➔
49# silo 3&4 test
connection
no
➔
49# silo 3&4 test
connection
yes
➔
49# silo 1&2 test
connection ok
49# silo 1&2 test
connection error !
Summary of Contents for TAK5-SA2-KFA-27-F1
Page 2: ......
Page 179: ...L Annex Example Milk ratio plan group A...
Page 180: ...M Annex Example Milk ratio plan group B...
Page 181: ...N Annex Form Feeding plan...
Page 182: ...O Annex Form Concentration plan...