95
Restricted/Ad Libitum Mode
10.8 Restricted/Ad Libitum Mode
By standard the automatic feeder operates in the restricted mode. Yet you can also commute
to the ad libitum mode.
In the restricted mode the automatic feeder operates with animal identification, i.e. the an-
imals are fed individually and in a restricted way and all data are recorded per animal.
In the ad libitum mode the automatic feeder operates without animal identification. In fee-
ding mode, a new portion is prepared each time the electrode in the mixer jar is free. If the
automatic feeder is equipped with two feeding stations, both box valves are open. The con-
centrate feeders dispense the next portion each time the feeding bowl is empty.
10.8.1 Restricted/Ad Libitum Mode (Automatic Feeder)
Turn the program switch to 10 = keyboard.
Enter 2 and press ENTER to confirm the input.
Select „yes“ for restricted mode or „no“ for ad libitum mode.
Press ENTER to confirm the input.
Go to the next screen. The display shows the milk amount
prepared yesterday and today.
Press Arrow Right to go to the next screen. Press ENTER.
Enter the milk ratio for the ad libitum portion. Press ENTER
to confirm the input.
Move to the next screen and press ENTER.
Enter the concentration for the ad libitum portion and press
ENTER to confirm the input.
Go to the next screen. Press ENTER.
Enter the additive amount for the ad libitum portion.
Press ENTER to confirm the input.
Restricted
Ad Libitum
2# restricted yes
ad lib
no
2# restricted yes
ad lib
no
2#
today:
12 L
ad lib yest.: 234 L
➔
2# ad lib
milk ratio
100 %
➔
2# ad lib
concentration120g/L
➔
2# ad lib
additive 0g/L
➔