Calibrating the Concentrate
8.5.3 Calibrating the Concentrate
The concentrate has to be calibrated separately for each concentrate station.
:
Clean the feeding bowl.
:
Press the calibration key at the corresponding concentrate station and wait until dosing
switches off automatically.
:
Remove the entire quantity from the feeding bowl and weigh it.
The quantity to be calibrated is distributed only if no animal is staying within the identifica-
tion range of the feeding station. The slide switch located at the Master station has to be on
position „Restricted“. If the slide switch is on position „Ad Lib“, switch over to „Restricted“
and press RESET until both red alarm LEDs light up. Then, release RESET.
Enter the calibration values into the Stand Alone.
Turn the program switch to 5 = calibration.
Select submenu „concentrate“. The submenus are displayed
only if the concentrate has been selected in Setup.
Press Arrow Right to go to the next screen.
Press Arrow Up or Arrow Down to select the concentrate silo
(1--4).
Press ENTER to confirm the input.
Press Arrow Right to move to the next screen.
Example for silo 1:
Press ENTER. Enter the quantity dispensed and weighed
during calibration.
Press ENTER to confirm the input.
Carry out the same calibration routine for all other registered silos.
Standard value for the calibration of concentrate: 0
calibration
concentrate
➔
^
calibration
concentrate silo:1^
➔
calibration
concentrate silo:1^
➔
silo 1 dosing
quantity:
0 g
➔