3. Result and status display tabs.
4. Control buttons.
Area 1 contains the following indicators:
Icon
Name
Description
Device info
Model name and serial number of the scanner. Serial number is a unique
identifier of the scanner and is assigned by the manufacturer.
Connection status
The status of connection with the scanner. If the connection is established,
the
Link
caption and the connection speed value will be displayed in this
field. The
Required
caption displays the recommended connection speed
required for correct operation of the device. The recommended speed
depends on the operation mode of the scanner. If communication with the
scanner is lost (for example, when the scanner is restarted or the
connection is broken), the web page will be displayed, but the connection
status will change to
Disconnected
.
Triggering mode
Measurement triggering mode, in which the scanner is operating now.
Profile settings
The current profile data format (
Format
) and the current number of profiles
per second (
FPS
) sent by the scanner via the UDP protocol. The value
may vary depending on the operating mode of the scanner and its settings.
Temperature °C
Processor temperature (
CPU
) and internal temperature of the scanner
(
Internal
) in °C. This information is used to assess the operating
conditions of the scanner. Do not allow the temperature to rise to 90°C or
more. When the permissible temperature is exceeded, the indicator starts
blinking.
Total work time
Operating time after switching on (
Work
) and total operating time of the
scanner (
Total
).
Area 2 contains the following tabs:
·
General
. General scanner settings, including parameters of CMOS-sensor and
data streams.
·
Profile processing
. Profile processing settings and control of profiles
accumulation in scanner memory.
·
Network
. Network settings of the scanner.
·
Triggering
. Settings of input channels of the scanner (triggering modes) and
output channel for synchronization of work of several scanners.
·
System
. System settings of the scanner, including support for compatibility
modes, etc.
Area 3 contains the following tabs:
·
Info
. General information about the scanner (firmware version, working range,
etc).
·
Viewer
. Viewing the current profile, or viewing profiles accumulated in internal
memory with the ability to display as a 3D point cloud, or viewing the intensity
image.
·
Video
. Video signal view.
·
Log data
. Information about the scanner operation.
Area 4 is located in the upper right corner and contains the control buttons: