RF627Weld [Revision 1.1.1] 03.08.2020
Laser Seam Tracking System for Welding Automation. RF627Weld Series
31
When you have changed search parameters, it is necessary to save them in order for the changes
to take effect.
15.5.3. Template parameters ("TEMPLATE" tab)
Templates consist of the lines (profile lines that the scanner ''sees"). These lines are
numbered starting from "0". The length and position of the lines are determined by special
parameters called
constraints
. To view / configure template parameters, double-click on the
template icon and go to the
TEMPLATE
tab.
The
TEMPLATE
tab contains a list of constraints that form a template description.
Each constraint is shown as follows:
·
Name of the constraint.
·
Line index (starts from 0).
·
Parameters for the specific constraint type.
When you have changed template parameters, it is necessary to save them in order for the
changes to take effect.
There are six types of constraints:
1. Line length
The constraint of the line length (
L
). This constraint is defined by the lower and upper
boundaries set in millimeters ("Minimum" and "Maximum" fields respectively). One or both
boundaries may be set as "Undefined".
2. Endpoint distance
The constraint of the distance (
L
) from the end of one line (
LineFrom
) to the start of
another line (
LineTo
). This constraint is defined by the lower and upper boundaries set in
millimeters ("Minimum" and "Maximum" fields respectively). One or both boundaries may
be set as "Undefined".
3. Rotation angle
The constraint of the angle of rotation (
Angle
) in degrees from one line (
LineFrom
)
to another line (
LineTo
). This constraint is defined by the lower and upper boundaries set in
millimeters.("Minimum" and "Maximum" fields respectively), and by the direction of rotation.
If any of the constraints is absent, set the values "Undefined" and "None" for lower / upper
boundaries and for the direction of rotation respectively.
NOTE:
The minimum and maximum values of the angle of rotation can vary in the
range of 0 to 180°.