32
Laser Seam Tracking System for Welding Automation. RF627Weld Series
RF627Weld [Revision 1.1.1] 03.08.2020
4. Endpoint shift in direction
The constraint of shift of the starting point of a line (
LineTo
) relative to the end of
another line (
LineFrom
). This constraint is defined by the lower and upper boundaries set in
millimeters ("Minimum" and "Maximum" fields respectively). If any of the constraints is
absent, it must be set as "Undefined". The direction of shift is defined by "Angle" that varies
in the range of -180° to 180° counterclockwise relative to the
LineFrom
line (if the
Angle
from the starting line
checkbox is selected), or to the
LineTo
line (if the
Angle from the
starting line
checkbox is not selected).
5. Endpoint distance with check
This constraint is similar to
Endpoint distance
, but has an additional verification on
the subject that the distance (
L
) from the end of one line (
LineFrom
) to the start of another
line (
LineTo
) is less than the distance between other ends (
La
). This prevents the situation,
in which the wrong lines can be used, because formally they can fit in the constraints.
6. Inclination angle
The constraint of the inclination angle (
Angle
). This constraint is defined by the
lower and upper boundaries ("Minimum" and "Maximum" fields respectively). If any of
constraints is absent, it must be set as "Undefined".
NOTE:
The values can vary in the range of -180° to 180°, positive values
correspond to the counterclockwise rotation.
15.5.4. List of measurements ("SELECT" tab)
The
SELECT
tab contains a list of measurements for the selected template.
When you have changed a list of measurements, it is necessary to click
in order for the
changes to take effect.
There are nine measurement types:
1. Line length
The line length in mm.
2. Intersection point