T
echnical
B
ulletin
PAGE: 47/58
Model:
Taurus-C1 / P1
Date:
21-Oct-11
No.:
RD074026
< Troubleshooting for Image Quality Problems \ Density Problems \ Color (2): Entire
Image Faint >
The following description was added in step 6 of “Solution”:
Note
•
"ACC" is machine calibration for copier jobs.
•
For printer jobs, execute Fiery calibration.
< Troubleshooting for Image Quality Problems \ Density Problems \ Color Is Too
Dense >
The following description was added in step 6 of “Solution”:
Note
•
"ACC" is machine calibration for copier jobs.
•
For printer jobs, execute Fiery calibration.
< Troubleshooting for Image Quality Problems \ Density Problems \ Broken Thin
Lines >
Before the Revision
After the Revision
3. Increase the value by 1 for all colors in [0204:
Adjust Line Width].
3. Increase/decrease the value by 1 for all colors in
[0204: Adjust Line Width] or with SP3-623-061 to
064.
< Troubleshooting for Image Quality Problems \ Gloss Problems \ Glossy Lines >
The description “Before Action” was deleted.
< Troubleshooting for Image Quality Problems \ Fusing-related Troubleshooting
\ Optimizing Productivity for Mixed Paper Size Use >
Before the Revision
After the Revision
Problem
The fusing temperature is normally adjusted for each
paper type and size.
Problem
The fusing temperature is normally adjusted for each
paper type.
< Troubleshooting for Image Quality Problems \ Fusing-related Troubleshooting
\ Insufficient Toner Fusing >
The description “Before Action” was deleted.