T
echnical
B
ulletin
PAGE: 38/58
Model:
Taurus-C1 / P1
Date:
21-Oct-11
No.:
RD074026
SC210:
Missing description was added.
Before the Revision
After the Revision
•
Cycle the machine off/on
•
Laser unit defective
•
Cycle the machine off/on
•
CK
Laser unit defective
SC220, SC222, SC224, SC226:
False description was corrected.
Before the Revision
After the Revision
50 ms (50 ms x2)
100 ms (100 ms x2)
SC240:
False description was corrected.
Before the Revision
After the Revision
•
YM
laser unit defective
•
CK
laser unit defective
False descriptions were corrected.
Before the Revision
After the Revision
SC260
C Laser Thermistor Error (
K
)
SC262
C Laser Thermistor Error (
C
)
One of the following occurred: ・
The reading of the thermistor in
the
CK
laser unit was less than
10°C (50°F), indicating that
the thermistor has disconnected.
・ The reading of the thermistor
in the
CK
laser unit was more
than 80°C (176°F), indicating
that the thermistor has shorted
out.
・ Cycle the machine off/on
・ IOB harness loose,
disconnected, broken, defective ・
CK
laser unit defective
・ IOB defective
SC260
C
Laser Thermistor Error (
CK
)
SC262
C
Laser Thermistor Error (
YM
)
One of the following occurred:
・ The reading of the thermistor in
the
CK or YM
laser unit was less
than 10°C (50°F), indicating
that the thermistor has
disconnected.
・ The reading of the thermistor in
the
CK or YM
laser unit was more
than 80°C (176°F), indicating
that the thermistor has shorted
out.
・ Cycle the machine off/on
・ IOB harness loose, disconnected,
broken, defective ・
CK or YM
laser
unit defective ・ IOB defective