T
echnical
B
ulletin
PAGE: 7/
8
Reissued:30-Jul-12
Model:
Taurus-C1/P1 (D074/D075/M044)
Date:
11-Jul-12
No.:
RD074078a
9. Finally, modify the intermediate values so that the values are proportionally increased
between the values determined in step 5 and step 8. Do not change SP2152-016, 080,
048, 112. These are set to 1.000 at the factory.
SP2152 – xxx
Black
Magenta
Cyan
Yellow
Set to
NOTE
001 065 063 127
002 066 062 126
003 067 061 125
Determined in
step 8
.
.
.
.
.
.
.
.
.
.
.
.
Proportionally-
increased
016 080 048 112
1.000
Do not
change
.
.
.
.
.
.
.
.
.
.
.
.
Proportionally-
increased
029 093 035 099
030 094 034 098
F
R
031 095 033 097
Determined in
step 5