T
echnical
B
ulletin
PAGE: 25/25
Model:
Taurus-C1a/C1b (D074/D075)
Date:
20-Mar-14
No.:
RD074118
Procedure required after cleaning the ITB speed sensors
Make sure to perform the following procedure after cleaning the ITB speed sensors.
1. Execute SP2-912-001 (Encoder Sn:Adj Light: Adj Light Amt).
2. Turn the main switch off and then on.
3. Execute SP2-914-001 (Encoder Sn:Get 1stPhase: Get Phases: Execute All).
4. Turn the main switch off and then on.
5. Check the value of SP2-915-001 (Encoder Sn Ctrl Condition: Scale FB Control Enable)
If the value is “1”, the feedback control is properly turned on.
If the value is “0,” repeat the sensor cleaning procedure until the value is “1”.
6. Execute SP3011-4 (Manual ProCon: Exe: Full MUSIC) to complete the procedure.