T
echnical
B
ulletin
PAGE: 5/14
Model:
Taurus-C1 (D074/D075)
Date:
22-Jun-2011
No.:
RD074015a
The following table is an excerpt from the reference table describing the SP codes and the
corresponding PM parts in the section "Preventive Maintenance > PM Tables for Main
Machines > ARDF > SP Setting Summary" of the service manual.
Procedures indicated “Yes” in
red
in the column “Installation” have been deleted.
Task Details
Installation
1
PM Parts
Applicable part only
‐
2
Set Toner Bottle
Yes
3
Open Front Doors
Both left, right doors
Yes
4
Main Power ON
Yes
5
Enter SP Mode
Yes
6
Reset PM Part
Applicable part only
‐
7 Install
Developer
SP3024-001(K)
SP3024-002 (C)
SP3024-003 (M)
SP3024-004 (Y)
Yes
8
Developer File OK?
SP3025-001
Results for YMCK
reading left to right
Yes
9 Apply
Lubricant
1.
Open right front door.
2. SP2310-001
3. Close right door.
‐
10 Close Front Door
Yes
11 Wait for Warmup ("Ready")
Wait 5 min. for the
audible beep and the
"Ready" message on
the operation panel.
Yes
12 Manual Toner Fill
SP3051-001
Yes
13 Cleaning
SP3032-001
(All)
SP3032-02 (CMY)
SP3032-03 (K)
SP3032-04 (C)
SP3032-05 (M)
SP3032-06 (Y)
Yes
14 Initialize TD Sensor
SP3030-01 (All)
SP3030-02 (CMY)
SP3030-03 (K)
SP3030-04 (C)
SP3030-05 (M)
SP3030-06 (Y)
Yes
15 Confirm TD Sensor Initialization
SP3031-001
Results for YMCK,
reading left to right.
Yes
16 Initialize Process Control
SP3020-001
Yes
17 Confirm Process Control Initialization
SP3012-001
Yes
18 Exit SP Mode
Yes