5.Troubleshooting
165
Test the Voltage Supplies
To check if the power supply is working, use a multimeter at the following locations on the power supply
unit.
Test the voltages on the ends of the connectors coming from the power supply unit. The following table
lists the power connectors.
REF. D.
PIN NO.
SIGNAL
WIRE COLOR
P1
1
+3.3V
ORANGE
2
+3.3V
ORANGE
3
COM
BLACK
4
+5V
RED
5
COM
BLACK
6
+5V
RED
7
COM
BLACK
8
PW-OK
GRAY
9
+5Vab
PURPLE
10
+12V
YELLOW
11
+12V
YELLOW
12
+3.3V
ORANGE
13
+3.3V
ORANGE
+3.3VS
BROWN
14
-12V
BLUE
15
COM
BLACK
16
PS-ON
GREEN
17
COM
BLACK
18
COM
BLACK
19
COM
BLACK
20
-
-
21
+5V
RED
22
+5V
RED
23
+5V
RED
24
COM
BLACK
P2
1
COM
BLACK
2
COM
BLACK
3
+12V
YELLOW
4
+12V
YELLOW
Summary of Contents for D3GF
Page 2: ......
Page 6: ......
Page 13: ...1 Installation 7 Installation Flow Chart Recommended installation steps are as follows ...
Page 46: ...1 Installation 40 If activation does not require a restart Server Option Client Option ...
Page 71: ...3 Replacement 65 Cover Removal Side Cover for the E 25C 1 Remove the side cover A ...
Page 93: ...4 System Maintenance 87 Command WorkStation For details refer to the Command WorkStation help ...
Page 187: ...7 Specifications 181 H 4 9 x 14 3 x 11 6 Weight 5 5 kg 12 2 lb ...