5.Troubleshooting
152
System Software Installation (USB Method)-1
Faulty HDD cable or HDD
Corrupted CMOS
Faulty motherboard
Faulty CPU
Suggested action:
1.
Make sure that the E-25C service switch 1 is set to ON and service switch 2 is set to OFF.
If the service switches are in the wrong position, turn OFF the E-25C, set the switches correctly,
turn ON the power, and allow the installation to resume.
2.
Turn OFF the E-25C, wait 10 seconds, and then turn it ON again.
3.
Check the LED on the USB flash drive.
If the LED is not blinking (remains OFF or solid), the USB flash drive may be improperly seated.
Turn OFF the E-25C, reseat the USB flash drive, turn ON the power, and then allow the
installation to resume.
4.
Retry the installation using a different USB flash drive.
5.
Reseat the cables to the HDD.
6.
Replace the HDD cable.
7.
8.
Replace the motherboard. [Link to
9.
System Software Installation (USB Method)-2
Symptom:
During installation, the LED on the USB flash drive remains OFF or solid (not blinking).
Possible cause:
One of the following:
Faulty or improperly seated USB flash drive
Faulty motherboard
Faulty HDD
Suggested action:
1.
Turn OFF the E-25C, reseat the USB flash drive, turn ON the power, and then allow the
installation to resume.
2.
Retry the installation using a different USB flash drive.
3.
Replace the motherboard. [Link to
4.
Reseat the cables to the HDD.
5.
Replace the HDD cable.
6.
Summary of Contents for D3GF
Page 2: ......
Page 6: ......
Page 13: ...1 Installation 7 Installation Flow Chart Recommended installation steps are as follows ...
Page 46: ...1 Installation 40 If activation does not require a restart Server Option Client Option ...
Page 71: ...3 Replacement 65 Cover Removal Side Cover for the E 25C 1 Remove the side cover A ...
Page 93: ...4 System Maintenance 87 Command WorkStation For details refer to the Command WorkStation help ...
Page 187: ...7 Specifications 181 H 4 9 x 14 3 x 11 6 Weight 5 5 kg 12 2 lb ...