5.Troubleshooting
158
Printing-4
Symptom:
Test page fails to print.
Possible cause:
Faulty HDD
Suggested action:
If replacing the HDD does not correct the problem, make sure you install the old HDD back into the
E-25C.
Printing-5
Symptom:
E-25C appears in the list of printers on the customer's workstation, but certain jobs do not print.
Possible cause:
PostScript error
Suggested action:
Make sure that Print to PostScript Error in Setup is set to Yes. Check for error messages on the E-
25C output.
Printing-6
Symptom:
E-25C appears in the list of printers on the customer's workstation, but certain jobs do not print.
Possible cause:
Application problem
Suggested action:
1.
Print a job from a different application to determine if the problem is associated with a particular
application.
2.
Make sure that the connection between the E-25C and the workstation is working by
downloading a test page from the workstation or printing a simple file, such as a text file.
3.
Resend the problem file.
Printing-7
Symptom:
Configuration page is completely or mostly blank.
Possible cause:
Missing, incorrect, or faulty DIMM(s)
Corrupted system software
Summary of Contents for D3GF
Page 2: ......
Page 6: ......
Page 13: ...1 Installation 7 Installation Flow Chart Recommended installation steps are as follows ...
Page 46: ...1 Installation 40 If activation does not require a restart Server Option Client Option ...
Page 71: ...3 Replacement 65 Cover Removal Side Cover for the E 25C 1 Remove the side cover A ...
Page 93: ...4 System Maintenance 87 Command WorkStation For details refer to the Command WorkStation help ...
Page 187: ...7 Specifications 181 H 4 9 x 14 3 x 11 6 Weight 5 5 kg 12 2 lb ...