Section 21 Electrical Characteristics
Rev. 3.00 Mar. 14, 2006 Page 767 of 804
REJ09B0104-0300
21.3.2
Control Signal Timing
Table 21.5 Control Signal Timing
Conditions: V
CC
= 4.5 V to 5.5 V, AV
CC0
= 4.5 V to 5.5 V, AV
CC1
= 4.5 V to 5.5 V,
V
SS
= AV
SS
= 0 V, I
φ
= 8 to 40 MHz,
T
a
= –40
°
C to +85
°
C (wide-range specifications)
Item Symbol
Min.
Max.
Unit
Test
Conditions
RES
setup time
t
RESS
200
ns
Figure
21.6
RES
pulse width
t
RESW
20
t
cyc
NMI setup time
t
NMIS
150
ns
Figure
21.7
NMI hold time
t
NMIH
10
ns
NMI pulse width (after leaving
software standby mode)
t
NMIW
200
ns
IRQ
setup time
t
IRQS
150
ns
IRQ
hold time
t
IRQH
10
ns
IRQ
pulse width (after leaving
software standby mode)
t
IRQW
200
ns
I
φ
RES
t
RESS
t
RESS
t
RESW
Figure 21.6 Reset Input Timing
electronic components distributor