![background image](http://html1.mh-extra.com/html/raymarine/a65/a65_installation-and-operation-instructions-manual_3915412047.webp)
600 watt sonar-compatible sonar transducer connection via
optional adaptor — Sonar variant multifunction displays
D12257-1
1
2
3
1.
Rear connector panel of multifunction display (Sonar variant).
2.
E66066 adaptor cable.
3.
Sonar transducer.
Transducer adaptor cable
Cable
Part number
0.5 m (1.64 ft) transducer adaptor
cable
E66066
Sonar transducer connection — Non-Sonar variant
multifunction displays
1
2
S
eaTalk
hs
/ RayNet
SeaTalk
hs
/
RayNet
3
6
5
4
D
12258-1
1.
Rear connector panel of multifunction display (Non-sonar
variant).
2.
Raymarine network switch (only required if connecting more
than one device using SeaTalk
hs
/ RayNet).
3.
RayNet cable.
4.
Raymarine sonar module.
5.
Sonar transducer cable.
6.
Sonar transducer.
Minn Kota sonar transducer connection via optional adaptor
cable (Sonar variant multifunction displays only)
D12259-1
1
4
2
3
1.
Rear connector panel of multifunction display (Sonar variant).
2.
Minn Kota transducer adaptor cable.
3.
Minn Kota transducer cable.
4.
Minn Kota transducer.
Sonar variant multifunction displays
The table below details which multifunction display variants feature
a built-in sonar module and can be connected directly to compatible
sonar transducers.
Sonar variants
Non-sonar variants
a67
a65
e7D
e7
c97
c95
c127
c125
e97
e95
e127
e125
e165
Minn Kota transducer adaptor cable
Connects a Minn Kota sonar transducer to a compatible Raymarine
multifunction display.
Cable
Part number
1 m (3.28 ft) Minn Kota transducer
adaptor cable
A62363
Thermal camera connection
You can connect a thermal camera to your New c Series or New
e Series multifunction displays.
Note:
New a Series does not support thermal cameras.
The camera is connected via a Raymarine network switch. If
you want to use the optional Joystick Control Unit (JCU) with the
camera this must also be connected to the network switch. A
composite video connection is required between the camera and
the multifunction display.
2
3
4
5
6
D12260-1
1
8
7
S
eaTalk
hs
/ RayNet
SeaTalk
hs
/ RayNet
SeaTalk
hs
/ RayNet
1.
Multifunction display
2.
Raymarine network switch
3.
Joystick Control Unit (JCU), optional
4.
SeaTalk
hs
to RayNet cable
5.
Ethernet cable coupler.
6.
PoE (Power over Ethernet) injector (only required if using the
optional JCU).
7.
Thermal camera
8.
Video connection
Important notes
• You can control the thermal camera using your multifunctional
display. The Joystick Control Unit (JCU) is optional, but can be
Cables and connections
47
Summary of Contents for A65
Page 2: ......
Page 4: ......
Page 8: ...8 New a Series New c Series New e Series...
Page 12: ...12 New a Series New c Series New e Series...
Page 20: ...20 New a Series New c Series New e Series...
Page 36: ...36 New a Series New c Series New e Series...
Page 64: ...64 New a Series New c Series New e Series...
Page 86: ...86 New a Series New c Series New e Series...
Page 96: ...96 New a Series New c Series New e Series...
Page 106: ...106 New a Series New c Series New e Series...
Page 138: ...138 New a Series New c Series New e Series...
Page 192: ...192 New a Series New c Series New e Series...
Page 202: ...202 New a Series New c Series New e Series...
Page 206: ...206 New a Series New c Series New e Series...
Page 218: ...218 New a Series New c Series New e Series...
Page 228: ...228 New a Series New c Series New e Series...
Page 232: ...232 New a Series New c Series New e Series...
Page 242: ...242 New a Series New c Series New e Series...
Page 248: ...248 New a Series New c Series New e Series...
Page 286: ...286 New a Series New c Series New e Series...
Page 300: ...300 New a Series New c Series New e Series...
Page 307: ......
Page 308: ...www raymarine com...