![Raymarine A65 Installation And Operation Instructions Manual Download Page 41](http://html1.mh-extra.com/html/raymarine/a65/a65_installation-and-operation-instructions-manual_3915412041.webp)
4.4 Power connection — New c Series
and New e Series
D12250-1
1
2
4
5
7
3
8
6
9
1.
Multifunction display connections.
2.
Power and data cable.
3.
Connection to 12/24 V power supply (e7/e7D is 12V only).
4.
Red cable (positive).
5.
Fuse.
6.
Black cable (negative).
7.
Video input cable.
8.
NMEA 0183 data cables.
9.
Shield (drain) wire (thin black wire; must be connected to RF
ground point).
Power distribution
Raymarine recommends that all power connections are made via a
distribution panel.
• All equipment must be powered from a breaker or switch, with
appropriate circuit protection.
• All equipment should be wired to individual breakers if possible.
Warning: Product grounding
Before applying power to this product, ensure it has
been correctly grounded, in accordance with the
instructions in this guide.
Grounding — Dedicated drain wire
The power cable supplied with this product includes a dedicated
shield (drain) wire for connection to a vessel's RF ground point.
It is important that an effective RF ground is connected to the
system. A single ground point should be used for all equipment.
The unit can be grounded by connecting the shield (drain) wire of
the power cable to the vessel's RF ground point. On vessels without
an RF ground system the shield (drain) wire should be connected
directly to the negative battery terminal.
The dc power system should be either:
• Negative grounded, with the negative battery terminal connected
to the vessel's ground.
•
Floating, with neither battery terminal connected to the vessel's
ground
Warning: Positive ground systems
Do not connect this unit to a system which has positive
grounding.
Power cable
The display is supplied with a combined power and data multi cable,
this can be extended if required.
Power cables available
Cable
Part number
Notes
1.5 m (4.9 ft) Straight
power and data cable
R62379
1.5 m (4.9 ft) Right
angled power and data
cable
R70029
Cable extension
The following restrictions apply to any extension to the power cable:
• Cable must be of a suitable gauge for the circuit load.
• Each unit should have its own dedicated power cable wired back
to the distribution panel.
Total length (max)
Supply voltage
Cable gauge (AWG)
12 V
18
0–5 m (0–16.4 ft)
24 V
20
12 V
14
5–10 m (16.4–32.8 ft)
24 V
18
12 V
12
10–15 m (32.8–49.2 ft)
24 V
16
12 V
12
15–20 m (49.2–65.5 ft)
24 V
14
Note:
These distances are for a 2 wire power cable run from the battery to
the display (approximately the distance from the battery to the display). To
calculate the round trip length, double the figure stated here.
Breakers, fuses and circuit protection
The power cable includes an in-line fuse. It is recommended that
you fit an additional thermal breaker or fuse at the distribution panel.
Fuse rating
Thermal breaker rating
7 A in-line fuse fitted within power
cable.
5 A (if only connecting one device)
Note:
The suitable fuse rating for the thermal breaker is
dependent on the number of devices you are connecting. If in
doubt consult an authorised Raymarine dealer.
Cables and connections
41
Summary of Contents for A65
Page 2: ......
Page 4: ......
Page 8: ...8 New a Series New c Series New e Series...
Page 12: ...12 New a Series New c Series New e Series...
Page 20: ...20 New a Series New c Series New e Series...
Page 36: ...36 New a Series New c Series New e Series...
Page 64: ...64 New a Series New c Series New e Series...
Page 86: ...86 New a Series New c Series New e Series...
Page 96: ...96 New a Series New c Series New e Series...
Page 106: ...106 New a Series New c Series New e Series...
Page 138: ...138 New a Series New c Series New e Series...
Page 192: ...192 New a Series New c Series New e Series...
Page 202: ...202 New a Series New c Series New e Series...
Page 206: ...206 New a Series New c Series New e Series...
Page 218: ...218 New a Series New c Series New e Series...
Page 228: ...228 New a Series New c Series New e Series...
Page 232: ...232 New a Series New c Series New e Series...
Page 242: ...242 New a Series New c Series New e Series...
Page 248: ...248 New a Series New c Series New e Series...
Page 286: ...286 New a Series New c Series New e Series...
Page 300: ...300 New a Series New c Series New e Series...
Page 307: ......
Page 308: ...www raymarine com...