Chapter 3 Configuring Your Library
Configuring I/E Station Slots
Scalar i500 User’s Guide
74
maximum of 18 dedicated I/E station slots.
Table 6
lists the number of
I/E station slots available per library for all base library configurations.
Table 6 Number of I/E Station
Slots Available
Details on configuring I/E station slots include:
• Before changing the number of I/E station slots, remove all tape
cartridges from any slots currently configured as I/E station slots.
• An I/E station that has been configured for storage may contain
cleaning slots. These cleaning slots must be deleted before you can
reconfigure the storage slots as I/E station slots.
• The default number of dedicated I/E slots is six. If you accept the
Setup Wizard
default configuration settings,
six I/E slots will be
created in the control module.
• If you increase the size of your library by adding expansion modules,
the I/E stations in the new modules will be storage slots by default.
You can select to reconfigure these slots as I/E slots.
• Based on the number of I/E slots you configure, the library
automatically determines which I/E stations to configure as I/E slots
and which to configure as storage.
Library
Configuration
5U Control Module
9U Expansion Module
Library Total
I/E Stations
I/E
Slots
I/E
Stations
I/E
Slots
I/E
Stations
I/E
Slots
5U
1
6
–
–
1
6
14U
1
6
1
12
2
18
23U
1
6
2
24
3
30
32U
1
6
3
36
4
42
41U
1
6
4
48
5
54