Chapter 7 Installing, Removing, and Replacing
Permanently Removing Expansion Modules From an Existing Library
Scalar i500 User’s Guide
233
Preparing to Permanently
Remove the 9U
Expansion Module
7
Follow these instructions to prepare to permanently remove the
expansion module:
Required tools:
• Phillips #2 screwdriver, for removing and replacing the top cover
plate
• T10 TORX screwdriver, for removing and replacing the bottom cover
plate
1
Remove all tape cartridges from the library using the import and
export commands of the operator panel or web client.
2
Reconfigure the library with the following settings:
• Partitions: 0
• Cleaning slots: 0
• I/E station slots: 6
3
Power off the library.
4
Disconnect all power cords, network data cables, and module-to-
module cables from each module you will be removing.
Warning:
All libraries taller than 14U must be installed in a rack
having a main protective earthing (grounding) terminal,
and power must be supplied via an industrial plug and
socket-outlet and/or an appliance coupler complying with
IEC 60309 (or an equivalent national standard) and having
a protective earth (ground) conductor with a cross
sectional area of at least 1.5 mm
2
(14 AWG).
To ensure proper airflow and access space, Allow 60 cm
(24 inches) in the front and back of the library.
Warning:
Without tape drives, tape cartridges, or power supplies, a
5U control module weighs approximately 58 lbs. A 9U
expansion module, without tape drives, tape cartridges, or
power supplies, exceeds 65 lbs.
To avoid serious injury, at least two people are required to
safely lift the modules into position.