MON_DESC_ERRORS
16Dh
Monitor
Despcriptor Errors detected
MON_CRC_ERROR
16Eh
Monitor
CRC checking error
MON_INVALID_PARAMETERS
16Fh
Monitor
Invalid parameters field in cmd packet
MON_NO_CARTRIDGE_INSERTED 170h
Monitor
No Cartridge inserted
MON_SERVO_MARGIN_DATA_IS_NOT_AVAILABLE
171h
Monitor
Servo Margin Data in not available
MON_ISR_UART_RCV_UNDERRUN_ERROR 172h
Monitor
MON_ISR_UART_RCV_HEADER_ERROR 173h
Monitor
MON_ISR_UART_RCV_TERMINATOR_ERROR 174h
Monitor
MON_ISR_UART_RCV_PORT_ERROR 175h
Monitor
MON_FLASH_OUT_OF_RANGE 176h
Monitor
Data
size to flash is out of allocated range
MON_FLASH_IMAGE_CHECKSUM_BAD 177h
Monitor
Firmware image file fails checksum
SRV_LPOS_NOTIFICATION_NOT_FOUND 178h
Servo
Delete lpos failed because it was not in the notify table.
SRV_LPOS_UNRECOGNIZED_LPOS_DELETE_MODE 179h
Servo
Delete mode not recognized as a valid enum.
SRV_LPOS_READ_DIR_INVALID 17Ah
Servo
Invalid direction in lpos notification check
SRV_MOVETAPE_REVERSE_PHYSICAL_LIMIT_UNDE
RRUN_DURING_RAMP_UP
17Bh
Servo
Physical limit in reverse direction exceeded in ramp up state.
SRV_MOVETAPE_RAMP_DOWN_FAILED_AT_LPOS_N
OTIFICATION
17Ch
Servo
A ramp down attempt was rejected by the fiq servo code during
SRV_MOVETAPE_RAMP_DOWN_FAILED_WHEN_REV
ERSING_DIR
17Dh
Servo
A ramp down attempt was rejected by the fiq servo code during
SRV_MOVETAPE_RAMP_DOWN_FAILED_WHEN_SPE
ED_CHANGE_REQUIRED
17Eh
Servo
A ramp down attempt was rejected by the fiq servo code during
SRV_MOVETAPE_TAPE_ACTIVE_CMD_NOT_VALID_F
OR_THIS_STATE
17Fh
Servo
In tape state machine
SRV_MOVETAPE_TAPE_RAMP_UP_FAILED_FROM_I
DLE_STATE
180h
Servo
Ramp up failed in srv_skip_to_lpos_in_idle transition function.
SRV_MOVETAPE_UNEXPECTED_MESSAGE_RESPON
SE_IN_CRUISE_CONTROL
181h
Servo
An unexpected message was received in the cruise control.
SRV_LPOS_REJECT_LPOS_SET_LPOS_NOTIFICATIO
N_BECAUSE_TABLE_IN_USE
182h
Servo
Notification table being updated by other task
SRV_MOVETAPE_RAMPDOWN_FAILED_DURING_LP
OS_UNDERRUN_IN_CRUISE_CONTROL
183h
Servo
Tape lpos underrun error during cruise control state.
SRV_MOVETAPE_RAMPDOWN_FAILED_DURING_LP
OS_OVERRUN_IN_CRUISE_CONTROL
184h
Servo
Tape lpos overrun error during cruise control state.
SRV_MOVETAPE_FORWARD_PHYSICAL_LIMIT_OVE
RRUN_DURING_CRUISE_CONTROL
185h
Servo
Physical limit exceeded in forward direction.
SRV_SEQ_TABLE_LOOKUP_ERROR
186h
Servo
Sequencer table incorrectly defined at compile time.
SRV_SEQ_MAXIMUM_STATE_EXCEEDED 187h
Servo
Sequencer index exceeded maximum number of functions in
table.
SRV_REEL_MAXIMUM_STATE_EXCEEDED 188h
Servo
Reel
task
state variable exceeded number of defined states.
SRV_CMDPROC_NOT_ENOUGH_TAPE_TO_RAMP
189h
Servo
Not enough tape is available to ramp up before a PBOT or
SRV_SEQ_PAST_LP1_REJ_INV_STATE 18Ah
Servo
Command
rejected since we are already past lp1.
SRV_SEQ_PAST_LP6_REJ_INV_STATE 18Bh
Servo
Command
rejected since we are already past lp6.
SRV_SEQ_REJ_NO_LP1
18Ch
Servo
Command rejected since tape parameters were not set.
SRV_CMDPROC_REJ_PARM
18Dh
Servo
Command rejected in command processor because
SRV_CMDPROC_REJ_INV_DIR 18Eh
Servo
Command
rejected
SRV_CMDPROC_REJ_CMD_NOT_ENOUGH_TAPE_TO
_RAMP
18Fh Servo Command
rejected
SRV_CMDPROC_REJ_CMD_TAPE_PAST_TARGET_LP
OS
190h Servo Command
rejected
SRV_CMDPROC_TAPE_NOT_STOPPED 191h
Servo
Command
rejected
SRV_REEL_UNKNOWN_TAPE_MOVE_COMMAND
192h
Servo
Reel task received a command not recognized
SRV_MOVETAPE_RAMPDOWNTAPE_API_BUSY_REJ
ECT
193h
Servo
Servo API function RampDownTape() returned busy status.
SRV_MOVETAPE_MOVETAPETRACK_API_BUSY_REJ
ECT
194h
Servo
Servo API function MoveTapeTrack() returned busy status.
SRV_MOVETAPE_MOVETAPE_API_BUSY_REJECT 195h Servo Servo API function MoveTape() returned busy status.
SRV_REEL_INVALID_MESSAGE_RECEIVED 196h
Servo
An
invalid message was received by the reel task.
SRV_REEL_DRIVEMOTOR_ON_API_BUSY_REJECT
197h
Servo
API call DriverMotor failed.
SRV_REEL_DRIVEMOTOR_OFF_API_BUSY_REJECT
198h
Servo
API call DriverMotor failed.
Summary of Contents for LTO 4